Cable Grounding Circulating Current On-line Monitoring System
Cable Grounding Circulating Current On-line Monitoring System

Cable Grounding Circulating Current On-line Monitoring System

Real-time monitoring of grounding circulating current
Essence insulation fault early warning
Automatic alarm and data locking
Send Inquiry

Product Introduction

 

The Cable Grounding Circulating Current On-line Monitoring System focuses on the dynamic tracking and analysis of key indicators in high-voltage cable circuits, promptly detecting potential faults such as insulation defects, aging, and multi-point grounding of the sheath. Composed of a grounding current sensor, operating current sensor, monitoring IED, and backend software, the system provides data acquisition, analysis, and management functions, helping to prevent cable overload, optimize load distribution, and improve the reliability and service life of the power supply system.

 

Product Attributes

 

Circulating Current Monitoring IED

image001

Operating Current Measurement: 1 Channel

Sheath Grounding Current Measurement: 6 Channels

Measurement Period: 5 seconds ~ 24 hours (configurable)

RS485 Interface: 1 Channel, Baud Rate 1200~19200bps (configurable)

Working Power Supply: AC220V

Grounding Circulating Current Sensor

image003

Sheath Grounding Current Sensor: 1mA~100A, Opening Diameter 38mm (others need customization)

Measurement Accuracy: ±1%

Protection Class: IP65

Working Ambient Temperature: -40℃~+65℃

Working Ambient Humidity: 95%Rh

Operating Current Sensor

image005

Sheath Operating Current Sensor: 1 Channel, 1mA~1000A (others need customization)

Measurement Accuracy: ±1%

Protection Class: IP65

Working Ambient Temperature: -40℃~+65℃

Working Ambient Humidity: 95%Rh

 

Equipment Characteristics

 

Real-Time Monitoring

Continuous tracking of cable grounding current enables early detection of abnormalities, helping prevent major failures caused by circulating current issues.

01

Ground Wire Anti-Theft

Detects sudden current changes indicating stolen ground wires and immediately identifies the location of the theft.

02

Sheath Insulation Monitoring

Continuous monitoring of sheath grounding current detects insulation damage in time, using a non-intrusive method that requires no line modifications.

03

Transient Over-Current Lock and Protection

Monitors transient over-current conditions in the grounding circuit, providing latching alarms and data references for cable operation and maintenance.

04

Automatic Alarm System

Automatically triggers multi-level alerts (onsite, central, and personnel notifications) with data archiving when parameters exceed limits.

05

 

image007
image009
image011
image013

 

Application Scenarios

 

Cable Tunnels

Centralized monitoring of long-distance cable grounding status, preventing theft and damage.

Cross-regional Power Transmission Projects

Analyzing circulating current distribution and optimizing load allocation.

Power Plant Areas

Preventing grounding faults and avoiding unplanned unit shutdowns.

Rail Transit Power Supply Systems

Ensuring reliable traction cable grounding and continuous power supply.

 

 

 

After-Sales Service

 

1. Remote Technical Support

24-hour response time, via WhatsApp/WeChat/email/Teams.

2. On-site Service

Engineers can be dispatched overseas for installation guidance, commissioning, and training.

3. Spare Parts Supply

International express delivery available for key spare parts (sensors, power modules).

4. Software Upgrades

Product upgrades and modifications, multi-language versions available upon request.

5. Training Materials

English operation manuals, installation videos, and maintenance guides provided.

 

 

Our Factory

 

image001
image003
image005
image007
image009
image011
image013
image015
image017

 

Our Certificate

 

image019
image021
image023
image025
image027
image029
image031
image033

 

FAQ

Q: What is the routine maintenance required for the Cable Grounding Circulating Current On-line Monitoring System?

A: Mainly, periodically check the sensor connections for secureness and clean the equipment surface. No complex maintenance is required.

Q: Why monitor grounding circulating current?

A: Excessive grounding circulating current can cause cable overheating, accelerate insulation aging, and in severe cases, lead to fires. Monitoring circulating current can provide early warnings and prevent accidents.

Q: Does installation require a power outage?

A: The sensor adopts a clip-on design, which can be installed without power interruption and does not affect the normal operation of the cable.

 

 

 

Hot Tags: cable grounding circulating current on-line monitoring system, China cable grounding circulating current on-line monitoring system manufacturers, suppliers, factory, Cable Grounding Circulating Current On line Monitoring System, Cable Monitoring Solutions, Cable Test Discharge Detection Instrument, Cable Partial Discharge Online Monitoring System, Cable fault locating equipment, Nano particle Detection System